Selectronix, Inc.

Woodinville, WA

A Custom Product Development and Design Consulting Company

 

Home
Up
Services
Search
Support
How To Buy
About
Contact Us

Load Controller Competitive Cross-Reference

Manufacturer

Product Series

Part Number

Description

Selectronix

Series 4000

Selectronix

2100 Series

Athena ®

 

 

 

Series “SC”

 

Circular Mode

Yes, See Note 1

Yes, See Note 2

 

Series “SU”

 

Up-Down Mode

Yes, See Note 1

No

 

 

 

Thermistor Input

Yes, See Note 1

No

Barber-Colman ® SP-10-0-0-5 10 step sequencer

Yes, See Note 1,6

SLC4000-8 & SLC4000-4

SLC2110

See Note 6

Cam Industries / Coates Heater ®

Mini-Step Control

 

60005050

4-Step Mini-Step

Yes, See Note 1

SLC2104

 

60005051

6-Step Mini-Step

Yes, See Note 1

SLC2106

 

 

60005052

8-Step Mini-Step

Yes, See Note 1

SLC2108              See Note 7, 8

 

Mini-Step Trailer Board

60005053

4-Step Mini-Trailer

Yes, See Note 1

SLC2154, use with SLC2108X           See Note 8

 

 

60005054

8-Step Mini-Trailer

Yes, See Note 1

SLC2158, use with SLC2108X           See Note 8

 

 

60005008

Load Limit Summation Card

Yes, SLC4000-x includes Load Limit function           See Note 1

No

 

Mini Sequencer

60005055

4-Step Mini-Sequencer

Yes, See Note 1

SLC2104              See Note 2, 8

 

 

60005057

8-Step Mini-Sequencer

Yes, See Note 1

SLC2108X            See Note 2, 7, 8

Cesco ® (Controlled Energy Systems Company)

PS-3 Series Step Control

 

Verify input type for compatibility with Selectronix controller

Up to 30 stages

Yes, See Note 1

Yes, Up to 36 stages

 

 

 

Slidewire input

Yes, See Note 1

Yes, See Note 2

 

 

 

Progressive Sequencing

Yes, See Note 1

Yes, See Note 2

 

 

 

Thermistor input

No, See Note 9

No, See Note 9

 

 

 

Manual Override Reset

No

No

PS-5-SC-110-5C 5 Step Basic Controller SLC4000-8, See Note 9

SLC2105,

See Note 9

PS-10-SC-110-5C 10 Step Basic Controller

SLC4000-8, SLC4000-4,SLC4020-1

See Note 9

SLC2110,

See Note 9

PS-15-SC-110-5C 5 Step Expansion Unit

See Note 9

SLC2155,See Note 9
PS-20-SC-110-5C 10 Step Expansion Unit

See Note 9

SLC2160,See Note 9
Cleaver-Brooks ® 798-01462-000 10 Step Expandable Controller Repl Unit >>>>>>>> SLC2110X
798-01464-000 10 Step Expansion Unit Repl Unit >>>>>>>> SLC2160
798-01468-000 3 Step Basic Controller Exact Unit >>>>>>>> SLC2103
798-01469-000 4 Step Basic Controller Exact Unit >>>>>>>> SLC2104
798-01472-000 10 Step Basic Controller SLC2110
798-01476-000 8 Step Expandable Controller Exact Unit >>>>>>>> SLC2108X
798-01480-000 2 Step Expansion Unit Exact Unit >>>>>>>> SLC2152
798-01482-000 6 Step Expansion Unit Exact Unit >>>>>>>> SLC2156

833-02535-000

8-Step Mini-Sequencer

Repl Unit >>>>>>>>

SLC2108X            See Note 7  

833-02536-000 6 Step Basic Controller Exact Unit >>>>>>>> SLC2106
833-02537-000 4 Step Basic Controller SLC2104
833-02539-000 8 Step Expandable Controller SLC4000-8 (Preferred) SLC2108X
833-02541-000 8-Step Mini-Trailer Repl Unit >>>>>>>> SLC2158
833-03553-000 12 Step Expandable Ctlr Exact Unit >>>>>>>> SLC2112X
833-03557-000 12 Step Expansion Unit Exact Unit >>>>>>>> SLC2162
833-03965-000 8 Step Controller with integral Load Limit Input (formerly provided by Load Summation Card) SLC4000-8 No
966-22670-000 10 step controller Exact Unit >>>>>>>> SLC2110
966-24788-000 8 Step Ctlr  - R851B-8 SLC4000-8 No
966-30325-000 4 Step Controller SLC4000-4 SLC2104
966-30339-000 6 Step Basic Controller Exact Unit >>>>>>>> SLC2106
966-31099-000 Cable, Cascading, 2 Unit Exact Unit >>>>>>>> SLC2195
996-31222-000 8 Step Expansion Unit Exact Unit >>>>>>>> SLC2158
996-31099-000 Cascading Cbl, 2 Unit Exact Unit >>>>>>>> SLC2195
996-31922-000 4 Step Basic Controller SLC4000-4 SLC2104

Hoffman®

744-HC series

 

Electronic Step Controller

Yes, See Note 1

Yes, See Note 2

Honeywell®

S684 Series

 

Step Controller

Yes, See Note 1,6

Yes, See Note 2,6

S984 Series 

S984A1034

Step Controller  

SLC4000-8

Yes, See Note 1,6

SLC2105

Yes, See Note 2,6

Indeeco ® (Solitech ®) M72 Series

201-M72-xx-05

5 Step Controller

SLC4000-8

201-M72-xx-10

10 step controller

(1) SLC4000-8 + (1)SLC4000-4

Indeeco ® (Solitech ®)

S95 Series  (1995-present)

 

Step Controllers

 

 

201-S95-M05-2A

5 step master, 2200 ohm  

Yes, See Note 1

No

 

 

201-S95-M05-2C

5 step master, 135 ohm input

SLC4000-8

SLC2105

 

 

201-S95-M05-2E

5 step master, 4-20ma input

SLC4000-8

SLC2105

 

 

201-S95-M05-2L

5 step master, 0-10V input

SLC4000-8

SLC2105, 2-10V control

 

 

201-S95-M05-2V

5 step master, adj VDCinput  

SLC4000-8

No

201-S95-M10-1S 10 step master SLC2110

 

 

201-S95-M10-2A

10 step master, 2200 ohm  

(1) SLC4000-8 + (1)SLC4000-4

No

 

 

201-S95-M10-2C

10 step master, 135 ohm input

(1) SLC4000-8 + (1)SLC4000-4

SLC2110X

 

 

201-S95-M10-2E

10 step master, 4-20ma input

(1) SLC4000-8 + (1)SLC4000-4

SLC2110X

 

 

201-S95-M10-2L

10 step master, 0-10V input

(1) SLC4000-8 + (1)SLC4000-4

SLC2110X

 

 

201-S95-M10-2V

10 step master, adj VDCinput  

(1) SLC4000-8 + (1)SLC4000-4

No

 

 

201-S95-S05-2

 

SLC4000-8

SLC2155

 

 

201-S95-S10-2

  10 step slave unit

(1) SLC4000-8 + (1)SLC4000-4

SLC2160 Use with SLC21xxX controller

 

 

202-S95-M05-2S-I

 

Yes, See Note 1

No

 

 

202-S95-M10-2S-I

 

Yes, See Note 1

No

 

 

202-S95-S05-2

 

Yes, See Note 1

No

 

 

202-S95-S10-2

 

Yes, See Note 1

No

 

 

204-S95-M05-2A-21

 

Yes, See Note 1

No

 

 

204-S95-M05-2A-41

 

Yes, See Note 1

No

 

 

204-S95-M05-2A-43

 

Yes, See Note 1

No

 

 

204-S95-M05-2A-47

 

Yes, See Note 1

No

 

 

204-S95-M05-2A-51

 

Yes, See Note 1

No

 

 

204-S95-M05-2A-55

 

Yes, See Note 1

No

 

 

204-S95-M10-2A-21

 

Yes, See Note 1

No

 

 

204-S95-M10-2A-41

 

Yes, See Note 1

No

 

 

204-S95-M10-2A-43

 

Yes, See Note 1

No

 

 

204-S95-M10-2A-47

 

Yes, See Note 1

No

 

 

204-S95-M10-2A-51

 

Yes, See Note 1

No

 

 

204-S95-M10-2A-55

 

Yes, See Note 1

No

205-S95-M05-2A-21

Yes, See Notes 1,  6

No

 

205-S95-M05-2A-41

 

Yes, See Notes 1,  6

No

 

 

205-S95-M05-2A-43

 

Yes, See Notes 1,  6

No

 

 

205-S95-M05-2A-47

 

Yes, See Notes 1,  6

No

 

 

205-S95-M05-2A-51

 

Yes, See Notes 1,  6

No

 

 

205-S95-M05-2A-55

 

Yes, See Notes 1,  6

No

 

 

205-S95-M10-2A-21

 

Yes, See Notes 1,  6

No

 

 

205-S95-M10-2A-41

 

Yes, See Notes 1,  6

No

 

 

205-S95-M10-2A-43

 

Yes, See Notes 1,  6

No

 

 

205-S95-M10-2A-47

 

Yes, See Notes 1,  6

No

 

 

205-S95-M10-2A-51

 

Yes, See Notes 1,  6

No

 

 

205-S95-M10-2A-55

 

Yes, See Notes 1,  6

No

Indeeco ® (Solitech ®)

S92 Series

S92M-A

Step Controllers  

Yes, See Note 1

Yes, See Note 2

 

 

S92M-B

 

Yes, See Note 1

Yes, See Note 2

 

 

S92S-A

 

Yes, See Note 1

Yes, See Note 2

 

 

S92S-B

 

Yes, See Note 1

Yes, See Note 2

Indeeco ® (Solitech ®)

208 Series

Triac output

 

 

 

 

 

 

208-1942

 

SLC4000-4, See Note 3

No

 

 

208-1943

 

SLC4000-4, See Note 3

No

Indeeco ® (Solitech ®)

S81 Series

Triac output

 

Step Controllers  

 

 

 

 

S81M-A

 

Yes, See Note 1

Yes, See Note 2

 

 

S81M-B

 

Yes, See Note 1

Yes, See Note 2

 

 

S81S-A

 

Yes, See Note 1

Yes, See Note 2

 

 

S81S-B

 

Yes, See Note 1

Yes, See Note 2

 

 

 

 

 

 

Indeeco ® (Solitech ®)

S71 Series

S71A

Step Controllers

Yes, See Note 1

Yes, See Note 2

 

 

S71A-B4-C  

 

SLC4000-4

SLC2104

S71A-B6-C   SLC4000-8 SLC2106
S71A-B8-C   SLC4000-8 SLC2108

Indeeco ® (Solitech ®)

S61 Series

Triac output

S61A

Step Controllers

Yes, See Note 1

Yes, See Note 2

Viconics® R851V-4 4 stage Step Controllers Yes, uses 120 VAC Control No
R851V-8 8 stage Yes, uses 120 VAC Control No
R851B-4 4 stage, boiler Step Controllers Yes, uses 120 VAC Control No
R851B-8 8 stage, boiler Yes, uses 120 VAC Control No

General Notes:

Many step controllers applications may be upgraded to use Selectronix controllers, especially when the capabilities are supplemented with those of a programmable electronic thermostat.  

Contact our Tech Support to determine if your application may benefit from an integrated solution!  

Note 1:   Series 4000

bulletStandard board size contain 4 or 8 relays.  The quantity to put in-service is field-configurable.
bulletStd field-selectable input voltage and current ranges, plus User-defined Input voltage or current  
bullet Up to 32 stages by cascading identical units, field configurable as expansion units.
bulletIntegral Load Limit input limits peak demand
bulletProvides an integral 0-10VDC vernier output, with indicating LED
bullet120 VAC control power  (For 24VAC/DC input power order SLC4024-4 or SLC4024-8)
bullet120VAC,  240VAC, or 24VAC contactor coil
bulletOpen board with standoffs.  Optional NEMA 4X enclosure with mounted board, is available

 

Note 2:   2100 Series

bulletFixed number of relays.  
bullet2 board sizes.  The small board accommodates from 1 to 6 relays, while the large board accommodates from 1 to 12 relays. 
bulletWith the maximum of 2 Expansion boards, the maximum stages is 36.
bulletSee the ‘2100 Series Ordering Guide’ to select the applicable part number. 
bulletNo vernier output signal is provided, use Series 4000, if required.
bulletNo thermistor input compatibility, use Series 4000, if required
bulletProgressive sequencing, if Linear sequencing is required, use Series 4000  
bullet120 VAC control power  
bulletFor 120 VAC contactor coil
bulletFor 240 VAC contactor coil,  special order for 240VAC or use Series 4000

 

Note 3:  SLC4000-4

bulletInput power is 120VAC instead of 24 V AC/DC 
bulletRelay output vs. Triac output
bulletVernier output is 0-10V analog 

  

Note 4:  2100 Series is compatible, see Series 4000 for new designs

Note 5:  2100 Series is compatible with special order for 0-10V, see Series 4000 for new designs  

Note 6:  Suggested functional replacement.  Call tech support to verify for specific applications
Note 7: SLC2108 for systems with 8 total relays.  Use SLC2108X for systems with more than 8 relays, and select an expansion board SLC215x to fulfill balance of system relays. For instance, a 12 step system order an SLC2108X and SLC2154, or for  a 16 step system order an SLC2108X and an SLC2158.  The connecting cable is included with the expansion board.
Note 8: CAM/Coates Conversion Wiring Diagrams:

CAM/Coates To Selectronix SLC2100 Wiring Diagram

CAM/Coates To Selectronix SLC4000 Wiring Diagram

Note 9: When replacing Cesco controllers that have a thermistor input, an external thermostat is required.  This may be an electronic unit such as a Honeywell T775 model, or a non-electronic unit such as a Honeywell T991A model.  Expansion units require a compatible expandable controller.

 

 
 
For General information or Customer Service:   customerservice@selectronix.us
For Technical Support:  techsupport@selectronix.us
For Sales: customerservice@selectronix.us
Send mail to webmaster@selectronix.us with questions or comments about this web site

Last modified: July 28, 2010